Disassembly and Reassembly

3-2 Disassembly and Reassembly

3-2-1 Checking the Device Condition

No.
1
Unfasten the two screws on the inspection window
of the Panel Front.
Slightly pull the lower part of the inspection win-
dow cover towards you and then pull it down to
remove the cover.
Open the rain cover.
The rain cover is connected via a ring to the device
in order to prevent loss.
- Operating the device with the rain cover opened
may cause rainwater to enter the C-BOX and
damage the PBA.
Use the inspection window on the Main PBA to
check the following.
- Error code
- Operation status (Key Switch K1- K4)
- Trial operation
- Pump down operation
- S-NET connection
(Specific operation information and the cycle-
related status value can be viewed.)
Samsung Electronics
Work Procedure
Remark
Inspection window
2
Rain cover
Screw
Screw
1
1
28

Advertisement