9-16 Datafill and subscription parameters
ITA configuration
To configure ITA on DTCI, the non-PRI trunk groups must be datafilled in
Table TRKSGRP along with PRI trunk groups.
Table TRKMEM
Table TRKMEM lists the data associated with each analog or digital trunk.
For PRI, this table defines the B-channels in each trunk group.
Example tuples
K2KPRI64CL 1 0 DTCI 10 0
K2KPRI64CL 2 0 DTCI 10 0 2
K2KPRI64CL 3 0 DTCI 10 0 3
Important fields
Important fields include:
ITA configuration
Non-PRI trunk members are datafilled in Table TRKMEM along with PRI
B-channels. The following example shows an ITA configuration.
Example tuples
K2KPRI64CL 1 0 DTCI 10 0 1
K2KPRI64CL 2 0 DTCI 10 0 2
K2KPRI64CL 3 0 DTCI 10 0 3
K2KABTRK1
K2KABTRK2
Important field
The AREASELECT field (in P-side links vector of the DTCI tuple in Table
LTCPSINV) must be DS1PRA for ITA.

PRI service-related tables

The parameters in the following tables describe the type and level of
services provided (or logical characteristics) on the PRI interface. These
tables are Table PRIPROF, Table LTDEF, and Table LTCALLS. The
mapping of these logical attributes to the physical interface is done through
Table LTMAP.
297-2521-106 Standard 23.01 March 2001
EXTRLNUM—external trunk number. The first digit of the key of this
external trunk number tuple should be (but is not required to be) the
same as the DTCI circuit time slot number to ensure that trunk selection
is done in the correct order.
PMTYPE—peripheral module type. The peripheral module type used for
PRI is DTCI.
1 0 DTCI 10 0 4
1 0 DTCI
10 0 5

Advertisement