6-4 PRI interworking

PRI-to-ISUP-to-PRI

Figure 6-1 illustrates PRI-to-ISUP-to-PRI call setup and takedown with
three-stage call clearing.
Figure 6-1
PRI-to-ISUP-to-PRI with three-stage call clearing
The call scenario in Figure 6-2 illustrates two-stage call clearing whereby a
Q.931 REL message maps into the ISUP REL message at the interworking
switch initiating call clearing (that is, the calling-access DMS-250 switch)
and an ISUP REL message maps into a Q.931 DISConnect message on the
other interworking switch (the called-access DMS-250 switch).
297-2521-106 Standard 23.01 March 2001
For active call clearing, an ISUP REL message is always mapped to a
Q.931 disconnect message.
(PRI)
PBX
SETUP
CALL PROC
Cut-through
ALERT
CONN
CONN ACK
DISC
REL
REL COM
Note: Dashed lines indicate optional messages.
(ISUP)
DMS-250
DMS-250
IAM
ACM
Network
cut-through
ANM
Active call
REL
RLC
(PRI)
PBX
SETUP
CALL PROC
Cut-through
ALERT
CONN
CONN ACK
DISC
REL
REL COM