Intended audience

This document provides references, procedures, and detailed information
about ISDN, and customer-deliverable features. Specifically, this document
describes how to apply PRI to a network—the DMS-250 switch hardware
configuration and available software features. This document is a reference
manual for operating company personnel using the ISUP DMS-250 switch.

Applicability of this document

This document is written for a DMS-250 office with software release
MWC18. More than one version of this document may exist. To determine
whether you have the latest version of this document, check the release
information in DMS-250 Master Index of Publications.

How to check the version and issue of this document

The version and issue of the document are indicated by numbers, for
example, 01.01.
The first two digits indicate the version. The version number increments
each time the document is updated to support a new software release. For
example, the first release of a document is 01.01. In the next software release
cycle, the first release of the same document is 02.01.
The second two digits indicate the issue. The issue number increments each
time the document is revised, but rereleased in the same software release
cycle. For example, the second release of a document in the same software
release cycle is 01.02.
To determine which version of this document applies to the software in your
office and how documentation for your product is organized, check the
release information in DMS-100 Family Guide to Nortel Publications,
297-1001-001.
This document is written for all DMS-250 Family offices. More than one
version of this document may exist. To determine whether you have the
latest version of this document and how documentation for your product is
organized, check the release information in DMS-100 Family Guide to
Nortel Publications, 297-1001-001.
Chapter 18, "MAUUI Over Release Message for NCAUUI," describes a
single switch scenario for MAUUI TSC clearing for NCAUUI.
Chapter 19, "MAUUI in First Call Clearing Message Before Connect,"
provides details on transporting the UUI information element from the
terminating to the originating agent.