2-4 DS-1 configuration
Table 2-2
Superframe format bit assignments
Frame
number
1
2
3
4
5
6
7
8
9
10
11
12
297-2521-106 Standard 23.01 March 2001
— BPV is an indication of a coding error in the received bit stream.
BPV indicates local span performance.
— CRC, applicable only with extended superframe format (ESF), is an
indication of one or more bit errors in a block of bits from the
received bit stream. CRC indicates performance on an end-to-end
span.
Channel framing identifies the location of time slot one. The signaling
frame identifies those frames in which two signaling states, A and B, are
transmitted on a time-shared basis. Table 2-2 shows the assignment of
the F-bit, A-bit, and B-bit; the most significant bit is defined as bit one
and the least significant bit as bit eight.
F-bit
terminal
framing
1
0
1
0
1
0
The superframe format is consistent with channel bank formats D2, D3,
and D4. The signaling bit is time-shared to identify the channel and the
signaling frame. The framing pattern is the repeated sequence
100011011100. The superframe format is supported on both types of
DS-1 cards (6X50AA and 6X50AB).
F-bit
PCM
signaling
coding
framing
bits
1–8
0
1–8
1–8
0
1–8
1–8
1
1–7
1–8
1
1–8
1–8
1
1–8
1–8
0
1–8
—end—