Procedure
To reset the device to the factory defaults during operation, follow the steps below:
1. Press the "SET" button.
2. Hold down the button for approximately 12 seconds.
After 9 seconds, the fault LED "F" flashes for 3 seconds.
– If you release the button after approximately 12 seconds, the device is restarted and the
– If you release the button before the 12 seconds have elapsed, the reset is canceled.
Enabling and disabling the button
In the configuration, you can enable or disable the button function.
3.5

LED display

3.5.1

LED "L"

The LED "L" shows whether the power supply is connected.
LED color
Green
-
3.5.2

"F" LED

The "F" LED shows the fault/error status of the device.
Meaning during device startup
LED color
-
Red
Red
Meaning during operation
LED color
-
Red
SCALANCE XF-200BA
Operating Instructions, 02/2023, C79000-G8976-C470-08
factory settings are restored.
LED status
Meaning
Lit
The power supply is connected.
With a redundant power supply, you can use the configuration to show
which power supply is connected.
Off
No external power supply is connected.
LED status
Off
On
Flashing
LED status
Off
On
Meaning during device startup
Device startup was completed successfully.
Device startup is not yet completed or errors have occurred.
There are errors in the firmware.
Meaning during operation
The device is operating free of errors. The signaling contact is
closed.
The device has detected a problem. The signaling contact has
opened.
Description of the device
3.5 LED display