Installer level – Overview
D
Setting level
INST.MENU → PV MODE →
PV MODE
INST.MENU → PV MODE → PRIORITY
PRIORITY
INST.MENU → DI SPLAY →
WATE R
AIR INLET
T_EV APOR
PV ECO
PV MAX
SHED DING
FAN CONTR.
INST.MENU → SET TINGS →
ANTI -BACT.
SHED DING
T°C MINI
FAN MODE
MAX. TIME
INST.MENU → RESE T PAR. →
RESE T PAR.
INST.MENU → COUN TERS →
COUN TERS
INST.MENU → LOCK ING →
LOCK ING
82
Values
Unit
Min.
Max.
Current value
Current value
Current value
Current value
Current value
Current value
Current value
Current value
Current value
60
70
Current value
43
43
Current value
2
24
h
Current value
Current value
Current value
Increment, select, explanation
YES, no
YES: PV MODE has higher priority than frost
protection and eco mode; no: PV MODE has
lower priority than frost protection and eco mode
Only visible if PV MODE = YES
0: Contact opened; 1: Contact closed
Only visible if PV MODE = YES
0: Contact opened; 1: Contact closed
Only visible if PV MODE = no
0: Contact opened; 1: Contact closed
Only visible if PV MODE = no
0: Contact opened; 1: Contact closed
1 °C; YES, no; number of days
Only visible if PV MODE = no
0: Product out of operation during high tariff
1: Only heat pump in operation during high tariff
2: Heat pump and immersion heater in operation
during high tariff
43 °C; no
1 = Fan operates only when the heat pump is
running. The fan speed automatically adjusts to
the heat pump's requirements.
2 = Fan operates only when the heat pump is
running. The fan runs at maximum speed.
3: Fan is controlled by an external humidistat
If PV MODE = YES: Only 1 and 2 can be selec-
ted
no, Auto, number of hours
YES, no
No. 1: Heat pump start cycles
No. 2: Immersion heater start cycles
No. 3: Not used
No. 4: Compressor operating hours
no; Auto; Pro
Installation and maintenance instructions 8000015884_00
Factory
setting
no
YES
no
1
no
1
no
no
no