Annual inspection and maintenance work – Overview
B
No.
Work
1
Check that the safety devices are functioning properly.
Check the refrigerant circuit for leak-tightness.
2
Check the hydraulic circuit for leak-tightness.
3
Check that the safety assembly is working properly.
4
Check whether the components of the refrigerant circuit show any signs of rust or traces of oil.
5
6
Check the unit's components for wear.
Check whether the unit's components are defective.
7
Check that the cables are securely seated on the connection terminals.
8
9
Check the electrical installation in accordance with the applicable standards and regulations.
10
Check the product's earthing.
Check the evaporator for ice formation.
11
Remove the dust from power supply connections.
12
Clean the evaporator carefully to avoid damaging the fins. Ensure that air circulation through the entire circuit, including
13
the air intake, is not impeded.
14
Check that the fan runs freely and is clean.
15
Check whether the condensate drains off without any problems.
16
Check the scale deposition on the immersion heater. If the layer of limescale is thicker than 5 mm, you must replace the
immersion heater.
Record the inspection/maintenance work carried out.
17
Fault messages – Overview
C
Fault code
Description
buS
PCB defective
Bus connection to the
display is faulty
Display defective
T_AI R
Air temperature sensor
defective (extracted air)
T_DE FROST
Evaporator temperature
sensor defective
(Defrosting temperature)
T_WA TER
Water temperature sensor
defective
CLOC K
Time
8000015884_00 Installation and maintenance instructions
Possible cause
Overvoltage in the
power grid
Cabling fault in the
power supply connec-
tion (low-tariff contact
or external fan control
system)
Damage during trans-
port
Sensor defective
Sensor not connected
to the PCB
Sensor cable damaged
Sensor defective
Sensor not connected
to the PCB
Sensor cable damaged
Sensor defective
Sensor not connected
to the PCB
Sensor cable damaged
Overvoltage in the
power grid
Damage during trans-
port
Solution
Replacing the PCB
Replacing the display
PCB
Replacing the display
connection cable
Replace the sensor
Replace the sensor
Replace the sensor
Replacing the display
PCB
Replacing the display
connection cable
Temporary operation
Product decommissioned.
Heat pump decommis-
sioned.
The selected back-up
heater keeps the water
temperature at 38 °C.
Heat pump decommis-
sioned.
The selected back-up
heater keeps the water
temperature at 38 °C.
Heat pump decommis-
sioned.
Operating times are no
longer considered:
Target temperature for do-
mestic hot water is per-
manently maintained (no
signal on connection plug
numbers 1 and 2).
79