Dual-circuit power supply heat pump tariff – 3~/N/PE 400 V (wiring diagram 4 =
D
1
7
6
5
N
L3
L2 L1
X102
1
Blocked power supply for internal auxiliary electric
heating
2
Power supply for control system
3
Continuous power supply
X110A
Optional power output for controller PCB (X110)
X110B
Optional power output for controller PCB (X110)
In this case, the heat pump is operated using two electricity tariffs (two consumption meters).
A continuous power supply ensures the operation of the compressor and the control PCB of the heat pump via its own elec-
tricity meter.
The power from the additional, blockable power supply for the internal electric back-up heater is supplied via a second elec-
tricity meter and can be suspended by the power supply network operator at peak times. The duration and frequency of the
outage is determined by the power supply network operator or must be clarified with them.
E
Installer level overview
Setting level
Installer level →
Enter code
Installer level → Fault list →
1)
F.086 – F.1120
Installer level → Test menu → Statistics →
Compressor hours
Compressor starts
1)
See overview of fault codes
0020196687_03 flexoTHERM exclusive Installation and maintenance instructions
L3
L2
L1
X110B
Values
Min.
Max.
00
99
Current value
Current value
2
L1
N
X110
X110A
X101
Mains connection for compressor
X103
Optional power output for auxiliary heating (X102)
X102
Mains connection for internal auxiliary electric heat-
ing
X110
Mains connection for heat pump controller PCB
Unit
Increment, select, ex-
planation
1 (competent person
code 17)
Deleting
h
Appendix
3
L1 L2
L3
N
X101
X103
Default setting
Setting
00
)
39