Glass Safety Barrier Removal:
1. Ensure the fireplace is operating properly and all firebox glass and liner panels are installed prior to installing the glass safety barrier.
2. Remove the protective peel from the glass safety barrier and clean the inner surface. Identify the hooks on the glass safety barrier;
these indicate the inner surface.
3. Attach the vacuum clamps to the glass as shown on the outer surface. Press the vacuum clamps against the glass, then close the clamps
while maintaining pressure on the glass.
4. Slide the corner protectors onto the bottom corners of the glass.
5. Holding the glass barrier in front of the unit, slide it up behind the top lip of the unit. Lift the barrier up as far as it goes, then hook the
barrier onto the unit.
Slide behind the top lip
6. Visually inspect that hooks are sitting over their pins and that the glass is sitting level and
centered in the opening.
7. Remove the vacuum clamps and corner protectors.
8. To remove the glass, see the owner's manual.