Wall Board/Drywall Installation; No Screw Zones - Regency City CV60EPV-NG Owners & Installation Manual

Direct vent
Table of Contents

Advertisement

Wall Board/Drywall Installation

WARNING! Risk of Fire! Comply with all minimum clearances to combustibles as specified.
Finishing Instructions
It is important to follow the framing and finishing instructions to ensure proper placement of fireplace into the surrounding framing/finishing materials.
Wall board materials 1/2 in. thick are specified in this installation manual to properly align with the optional finishing methods offered with this appliance.
The CV60E-1 may be finished to the appliance opening with 1/2 inch thick drywall.
• Ensure that the back and side clearances are maintained.
WARNING! Risk of Fire! Maintain specified air space clearances to combustibles. Inadequate air space could cause overheating and fire.
DO NOT use screws more than 1/2 inch in length on the lower access cover panel. Longer screws may penetrate gas line or damage valve or electrical
components.
Note: It is acceptable to use a high temperature silicone sealant to adhere drywall to lower access cover panel.
The appliance is designed to be used with a minimum 1/2 in. wall sheathing materials such as drywall, plywood, wood composites, or non-combustible materials.
Thicker materials may be used. Refer to facing and finishing details in this manual.
Facing Material
• Facing and/or finishing materials must never overhang into the glass opening. See finishing details in this manual.
• Facing materials may be combustible or non-combustible
WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as speci-
fied in this manual. Overlapping materials could ignite and will interfere with proper operation.
PAINTING
If desired finishing includes a painted wall, 100% acrylic latex, oil-based or standard acrylic paints may be used.
Follow paint manufacturer's instructions for paint and primer application.

No Screw Zones

No screw zones (in shaded areas) as shown below must be adhered to.

NO SCREWS IN SHADED ZONE
NE PAS POSER DES VIS DANS LA ZONE OMBRAGÉE
installation
City Series CV60E-1 |
41
909-40

Advertisement

Table of Contents
loading

This manual is also suitable for:

City cv60e-1City seriesCity cv60e-ng