6 I/O Interface
FH-VPX-F210
 Connection Structure
PLC, terminal blocks or
other products
Connector
No.
CN1
CN2
CN3
 Cable
10.3
6 - 42
Connecting the FZ-VP
and the FH-VPX-
* After the connection, lock it securely.
F160-VP
Connection Destination
Connect to the parallel port CN1 of the FH Sensor Con-
troller.
Connect to the parallel port CN2 of the FH Sensor Con-
troller.
Connect to the Parallel I/O cable F160-VP.
CN3
CN3
CN1
CN2
FH-VPX-F210
Even if you connect the revers CN1
and CN2, Sensor Controller does
not perform.
It is immune to breakdown.
500
Vision System FH/FZ5 series Hardware Setup Manual (Z366)
FH controller
Parallel connector
(CN1/CN2)
Power supply used
in the FH controller:
Power supply S8VS
series (24 VDC)
Special Notes
(Unit: mm)