Wiring
The power connection for the Touch Panel Monitor is on the back side of the Monitor.
Connect the 24 VDC power source.
24 VDC
Power supply
24 VDC
• Keep the power supply wires as short as possible. (Max.2 m)
• If UL's certification is required, use a UL class II power supply.
• Use the cables and crimping terminals with the specified dimensions.
Do not directly connect an electric wire that is simply twisted to the terminal block.
• Recommended wire size: AWG 13 to 22 (0.326 to 2.62 mm
• Terminal screw: M4 (Tightening torque: 1.0 N•m)
• Crimping Terminal
8.0 mm max.
Dimensions
26
270
7.74
306.52
322
161
180
Note 1. Panel thickness: 1.6 to 4.8 mm
2. No burr allowed
Vision System FH/FZ5 series Hardware Setup Manual (Z366)
M4
Recommended model
by OMRON:
S8VS-03024
8.0 mm max.
26
7.74
8-M4 Effective
screw length6
Mounting plate
(19)
thickness 1.6-4.8
3 Configuration
2
)
100
Panel cutout dimensions
75
37.5
3
+1
307
0
3 - 75