Installing An Lff Non-Hot-Plug Drive In The Drive Cage - HP ProLiant ML30 Gen10 User Manual

Table of Contents

Advertisement

Installing an LFF non-hot-plug drive in the drive cage

Installing an LFF non-hot-plug drive in the drive cage
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode: Position the tower server for hardware configuration.
If the server is in rack mode: Remove the server from the rack .
5. Remove the front bezel .
6. Remove the access panel .
7. If installed, remove the air baffle .
8. If there are drives already installed in the non-hot-plug drive cage, disconnect all cables from the drives .
9. Remove the non-hot-plug drive cage:
a. Remove the screws from the drive cage.
b. Remove the non-hot-plug drive cage.
10. Install the drive.
Installing an LFF non-hot-plug drive in the drive cage