Digital Monitor - Icom IC-905 Basic Manual

All mode transceiver
Hide thumbs Also See for IC-905:
Table of Contents

Advertisement

8
SET MODE
DV/DD Set
» SET > DV/DD Set

Digital Monitor

Selects a receive mode when
DV mode.
• Auto:
Receives in the DV mode or the FM mode,
depending on the received signal.
• Digital: Receives in the DV mode.
• Analog: Receives in the FM mode.
Digital Repeater Set
Turns the Digital Repeater Set function ON or OFF.
When accessing a repeater that has a call sign that
is different than the transceiver's setting, this function
reads the repeater's transmit signal and automatically
sets the repeater call sign.
• OFF: Turns OFF the function.
• ON: Automatically sets the repeater call sign.
DV Auto Detect
Turns the DV mode Automatic Detect function ON
or OFF. When in the DV mode, if you receive a non-
digital signal, this function automatically sets the
operating mode to the FM mode.
• OFF: Turns OFF the function. The operating mode
is fixed to the DV mode.
• ON: Automatically selects the FM mode for
temporary operation.
RX Record (RPT)
The transceiver can record the data of up to 50
individual calls. When the received signal includes a
status message ("UR?" or "RPT?") that is sent back
from the access repeater, you can record up to 50
messages, or only the last call, in the Received Call
Record.
• ALL:
Records up to 50 calls.
• Latest Only: Records only the last call.
BK
The Break-in (BK) function enables you to break
into a conversation, where the two other stations are
communicating with call sign squelch enabled.
• OFF: Turns OFF the function.
• ON: Turns ON the function.
L The BK function is automatically turned OFF when the
transceiver is turned OFF.
EMR
The Enhanced Monitor Request (EMR) function
enables all transceivers that receive an EMR signal
in the DV mode automatically open their squelch to
receive the signal.
(Default: Auto)
is pushed in the
L The EMR function is automatically turned OFF when the
EMR AF Level
Sets the audio output level when an EMR
communication mode signal is received.
(Default: ON)
When an EMR signal is received, the audio will be
heard at the programmed level, or the transceiver's
audio level, whichever is higher. To disable the setting,
set to "0."
(Default: OFF)
DD TX Inhibit (Power ON)
Selects the TX INHIBIT setting when the transceiver is
turned ON.
DD Packet Output
Sets the condition for outputting the packets in the DD
mode.
(Default: ALL)
(Default: OFF)
8-10
• OFF: Turns OFF the function.
• ON: Turns ON the function.
transceiver is turned OFF.
NOTE: After an EMR signal disappears, the audio
level will remain at the EMR level. In this case, rotate
to adjust the audio level.
• OFF: Sets to OFF.
• ON: Sets to ON.
• Normal: Outputs packets when:
- A call addressed to your own call sign or
a non-call sign specific call (CQCQCQ) is
received.
- An EMR signal is received.
- A break-in call is received.
• All:
Outputs all packets.
(Default: OFF)
(Default: 50%)
(Default: ON)
(Default: Normal)

Advertisement

Table of Contents
loading

Table of Contents