Line Voltage Requirements; Power Supply Location - Amana ART6610 Series Owner's Manual

Self-cleaning electric range
Hide thumbs Also See for ART6610 Series:
Table of Contents

Advertisement

Rectangular Anti-tip Bracket
1. Measure 3
1
/
inches from back wall on right and left
2
side of cabinet cutout. Mark measurements on floor
and draw a straight line connecting marks.
2. Position anti-tip bracket.
• If range is installed beside cabinet(s), place anti-tip
bracket with back edge on line drawn on floor and
side of bracket against cabinet.
• If range is not installed beside cabinet(s), position
range where it will be installed. Draw a line along
side of range on floor from front to back. Remove
range. Place anti-tip bracket with back edge over
line drawn 3
1
/
inches from back wall and side of
2
bracket over line drawn along side of range on floor.
• Anti-tip bracket can be installed on either right or
left side.
3. Mark 2 hole locations in anti-tip bracket.
4. Drill 2 holes.
• If drilling into wood, use a
• If drilling into concrete, use a
bit and insert plastic anchors.
5. Secure bracket to floor using screws supplied.
6. Slide range into position.
7. Remove range storage drawer and confirm anti-tip
bracket is engaged with range leveling leg.
3 1/2"
or
3
/
inch drill bit.
32
3
/
inch masonry drill
16

Line Voltage Requirements

Line voltage must not exceed rated voltage. Line voltage
less than rated voltage will result in slow heating. Wiring
system must conform to Underwriters Laboratories, Inc.
standards and National Electrical Code. Installation must
conform to all local, municipal and state building codes,
and local utility regulations. Range must be connected only
to a supply circuit as specified on rating plate of range.
This range requires 3 wires, 120/240 Volts, 60 Hertz A.C.
See rating plate attached to range for kilowatt rating.
House wiring and fusing must comply with local wiring
codes. If no codes apply, wire according to National
Electrical Codes.

Power Supply Location

Shaded areas show range clearance for electrical
connection.
A
B
A—3 inches
B—7 inches
C—6 inches
D—30
1
/
inches minimum
8
7
C
D

Advertisement