Technical Specifications - Siemens SIMATIC RTLS4030T EX1 Operating Instructions Manual

Localization systems
Table of Contents

Advertisement

Technical specifications

Table 5- 1
Technical specifications of the RTLS4030T EX1 transponder
Product name
PULSE radio frequencies (localization)
Wireless method
Transmission speed
Operating frequency rated value
Bandwidth
Frequency range
Transmit power
Range
Accuracy of the localization (typical)
Antennas
PHASE radio frequencies (communication and optional localization)
Wireless method
Transmission speed
Operating frequency rated value
Bandwidth
Frequency range
Transmit power
Range
Accuracy of the localization (typical)
Antennas
Supply voltage
Supply voltage
Service life (at 20 ℃)
SIMATIC RTLS4030T EX1
Operating Instructions, 12/2022, C79000-G8976-C677-01
SIMATIC RTLS4030T EX1
IEEE 802.15.4-2015 UWB HRP PHY
850 Kbps
3993.6 MHz (UWB channel 2; CE)
6489.6 MHz (UWB channel 5; CE)
499.2 MHz
3100 MHz ... 4800 MHz (CE)
6000 MHz ... 7000 MHz (CE)
0.037 mW (-41.3 dBm/MHz)
Maximum 30 m
0.2 m
Built-in UWB antenna
IEEE 802.15.4
1 Mbit/s
2400 ... 2480 MHz ISM band
2 MHz; data transmission on 802.15.4; channels
configurable
2400 MHz ... 2483.5 MHz
Maximum 4 dBm (configurable)
Maximum 50 m
1 m
Built-in 2.4 GHz antenna
2 x CR123A-type: 3 V lithium batteries
Brand: VARTA (1550 mAh) or Panasonic (1400 mAh)
Standby: 2 years
Operation: 100 % UWB localization with 1 second: 12 months
5
6GT2700-3DA03-0EX1
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

6gt2700-3da03-0ex1

Table of Contents