Omron V330-F Series Connection Manual page 78

Auto focus multi code reader general ethernet (tcp/ip) connection guide
Hide thumbs Also See for V330-F Series:
Table of Contents

Advertisement

Timeout Error/TCP Connection Status Error
The timeout error codes for open processing, send processing, and receive processing are set
in H400, H401, and H402, respectively. The timeout error code/TCP connection status error code
for close processing is set in H404.
(O: Open processing, S: Send processing, R: Receive processing, C: Close processing, ○: Applicable processing)
Error code
O
0000
F101
F201
F301
F401
F402
FFFF
Code Reader Error Code
The error codes of code reader errors detected in receive processing are set in H403.
(O: Open processing, S: Send processing, R: Receive processing, C: Close processing, ○: Applicable processing)
Error code
O
0000
F302
FFFF
* "ER" is the only error response supported for communications errors. For details, check the monitor
information on the code reader.
S
R
C
Normal end
Open processing not completed within specified time
Send processing not completed within specified time
(This includes cases where response to be received was not
received.)
Receive processing not completed within specified time
Close processing not completed within specified time
Normal TCP connection status not shown within specified time
after close processing
Processing skipped for some reason
S
R
C
Normal end
Response from code reader is "ER"
Judgment of code reader error not made due to no response from
code reader for some reason
9. Software Part
Description
Description
78