Omron V330-F Series Connection Manual page 65

Auto focus multi code reader general ethernet (tcp/ip) connection guide
Hide thumbs Also See for V330-F Series:
Table of Contents

Advertisement

No.
Overview
3.1.
Send Processing Start
3.2.
Socket
Service
Area Setting
3.3.
Send Request Switch ON
No.
Overview
Normal/Error Judgment
3.4.
Processing
3.5.
Error Code Storage Area
Setting
Starts send processing.
The send processing ends by moving to receive or close
processing.
Parameter
Sets parameters required for send processing.
・ Sets the number of bytes of send data.
・ Sets the address type of the send data storage area.
・ Sets the first word of the send data storage area.
・ Clears the response code storage area.
Starts the send processing monitor timer and turns ON the
dedicated control bit for send processing request.
Makes judgment of "normal/error end" or "timeout error" as a result of
send processing.
The processing goes to receive processing if normal end or to close
processing if error end.
Sets #0 in the error code storage area if the judgment in 3.4.
Normal/Error Judgment Processing is "normal end".
Sets the following values in the error code storage area if judgment
in 3.4. Normal/Error Judgment Processing is "error end".
・ Response code error: Response code
・ Timeout: # F201
Refer to 9.7. Error Code List for details on error response codes.
9. Software Part