7.4.13 Installing Batteries into the Wheelchair

WARNING!
Risk of Serious Injury
Improperly installed battery tray can cause
instability resulting in serious injury.
– Ensure batteries and battery tray are installed
properly to maintain stability.
Fig. 7-35 Wheelchairs Manufactured Before 11/01/2018, ALL
Wheelchairs with 5° or 10° Fixed Anterior Assist and ALL
Wheelchairs for Australia or New Zealand
Fig. 7-36 Wheelchairs Manufactured After 10/31/2018 without
5° or 10° Fixed Anterior Assist
Positioning of the batteries into the battery tray
is completed with battery tray positioned in
wheelchair and partially pulled out. Illustrations
are shown without the wheelchair for clarification
purposes only.
1195667-E
1. Position the battery with the dual connector bracket
(one side of the connector for the controller and the
other side is for the remaining battery) M against the
back edge of the battery tray I in the orientation
as shown.
Batteries MUST be installed in the orientation
shown so that the wiring harnesses can be
connected together.
2. Position the remaining battery L between the battery
on the tray M and battery stop C.
3. Connect batteries together K.
When connecting battery straps, pull battery
straps tight to ensure there is no battery
movement.
4. Connect battery straps J.
5. Slide the battery tray I into the wheelchair.