7.6 DAY OF THE WEEK
Indicates the day of the week of the displayed programme. A setting can be made for each day, from Monday to Sunday
(Mo,Tu,We,Th,Fr,Sa,Su) or else for all work days from Monday to Friday (MF), or else for weekends from Saturday to
Sunday (SS). This system allows the setting of a single programme to turn the stove on or off every day, from Monday to Fri-
day, at the same time.
7.7 HOUR
Stove on or off hour.
7.8 MINUTES
Stove on or off minutes.
7.9 TEMPERATURE
For ignition programmes, the requested ambient temperature must be set between 5 and 30°C.
7.10 REQUESTED PROGRAMME
For ignition programmes, the requested heating programme must be set between 1 and 5.
7.11 PROGRAMME TYPE
Set either an ignition programme, ON, or power off programme, OFF.
7.12 PROGRAMME ENABLING
This function is essential, because if in the disabled position (No A.) the system will not control the programme and the pro-
gramme function may not be executed.

7.13 EXAMPLE OF PROGRAMMING

To programme the stove so that it turns on every day from Monday to Friday at 8am at level 4, with a temperature of 20°C,
proceed as follows after opening the ignition programme setting.
With TEMP+ select MF as the ignition days from Monday to Friday.
Select the Hour using the PROG+ key and set 08 with the TEMP+ and TEMP- keys.
Select the minutes using the PROG+ key and set 00 with the TEMP+ and TEMP- keys.
Select the temperature using the PROG+ key and set 20° with the TEMP+ and TEMP- keys.
Select the heating power using the PROG+ key and set 4 with the TEMP+ and TEMP- keys.
Select the mode using the PROG+ key and set ON with the TEMP+ and TEMP- keys.
Select the programme type using the PROG+ key and set Enab. with the TEMP+ and TEMP- keys.
Press SET to save the data and insert a new ignition programme. If programming is complete, press STOP to exit.
Remember to set the operating mode to Automatic to enable control of the weekly programmer.
7.14 THERMOSTAT MODE
Fig. 20
Press SET to open and modify the operating mode for temperature control or automated ignition and power off .
7.15 INTERNAL THERMOSTAT
Operating mode that regulates stove operation based on the detected ambient temperature. The stove is ignited both manu-
ally and automatically by the settings of the incorporated weekly programmer or internal timer. The stove power is automati-
cally controlled based on the set temperature, optimising heating with significant pellet savings.