Seal & Spacer Tools & Replacement - Pentair Fleck 2510 Service Manual

Hide thumbs Also See for Fleck 2510:
Table of Contents

Advertisement

SEAL & SPACER TOOLS &
REPLACEMENT
Figure 5
NOTE: Photos shown are for reference only for replacing
the seal and spacer. Actual valve may be different.
1. Turn off water supply to valve. Next, cycle valve to
backwash position, then to service. Now remove electrical
plug from outlet.
2. Remove control box cover.
3. Disconnect the brine line from the injector housing to the
brine valve (if your unit has timed brine tank fill).
4. Remove the two capscrews that hold the back plate to the
valve.
5. Grasp the back plate on both sides and slowly pull end plug
and piston assembly out of the valve body (see Figure 6)
and lay aside.
Figure 6
22 • JA12 Fleck 2510 & 2510 Econominder
6. Remove the seal first using the wire hook with the finger
loop (see Figure 7).
Figure 7
7. The spacer tool (use only for removing the spacers) has
three retractable pins, retained by a rubber ring, at one end.
They are retracted or pushed out by pulling or pushing the
center button the opposite end.
8. Insert the pin end of the spacer tool into the valve body with
the pins retracted (button pulled back). Push the tool tight
against the spacer and push the button in, (see ?). When
the button is pushed in, the pins are pushed out to engage
the 1/4 dia. holes in the spacer. Remove the tool from the
valve body. The spacer will be on the end. Pull the center
button back, the pins will be retracted and the spacer can
be removed from the spacer tool.
Figure 8
9. Alternately remove the remaining seals and spacers in
accordance with steps No. 6 and 8.
10. The last or end spacer does not have any holes for the pins
of the spacer tool to engage, therefore if the end spacer
does not come out on the first try, try again using the wire
hook with the finger loop.
11. To replace seals, spacers and end ring, use special tool
with the brass sleeve on one end. This is a double-purpose
tool (see ?). The male end acts as a pilot to hold the
spacers as they are pushed into the valve body and the
brass female end is used to insert the seals into the valve
body.