D7212GV3 | Operation and Installation Guide | 4.0
Service Walk Test Procedure
Refer to Figure 5 on page 19 for Service Walk Test
options. Refer to the Walk Test procedures in the
GV3 Series Owner's Manual Supplement
(P/N: F01U143082) when using a D1260 or D1260B
Keypad.
1. Choose a keypad to conduct the test. Ensure that
the display shows the idle disarmed text.
2. Press the [MENU] key to enter the Function List.
Press [NEXT] repeatedly until the SERVICE
WALK ? prompt appears.
3. Press [ENT].
The D7212GV3 does not include the
Service Walk Test in the Service Menu.
Enabling the Service Walk Test function
Function List provides access to the
Service Walk Test.
4. The display shows ### PTS TO TEST .Test the
first detection device.
5. When a detection device is faulted, the keypad
emits a brief tone and displays the point text of
the point tested for 60 sec. After 60 sec, the
display returns to the ### PTS TO TEST
message.
18
Installation
Extra Points display default text: If the switches on
a POPIT are set incorrectly to a point number that is
not in the program for the control panel, the default
text for that point number (PT ###) appears when the
point is faulted. Refer to the control panel's program
record sheet for the default text for all points.
Faulting the point a second time produces the tone
and shows the point text, but does not decrease the
count in the ## PTS TO TEST message.
1. To see the points that remain untested during the
Service Walk Test:
Press [ESC] when point text appears. The
a.
display shows ## PTS TO TEST.
b. Press the [ESC] key. VIEW UNTESTED ?
appears.
Press [ENT]. ## PTS UNTESTED appears.
c.
d. Press [NEXT] to see a list of the points that
have not yet been tested. Move through this
list by pressing the [NEXT] key.
To resume the Service Walk Test, press
e.
[ESC]. ## PTS UNTESTED appears.
Press [ESC]. ## PTS TO TEST appears.
f.
g. Resume testing points. To end the Service
Walk Test, press [ESC] twice.
2. After the last point is tested, 0 PTS TO TEST
appears. Press [ESC]. The display shows ALL
PTS TESTED briefly before returning to idle text.
Automatic time-out returns the system to
idle text. If there is no point or keypad
activity for 20 min, the Service Walk Test
ends automatically. The keypad returns to
idle text.
Bosch Security Systems, Inc. | 10/10 | F01U143079-03