Chapter 4 - AT Commands, S-Registers and Result Codes
Command:
%E n
Values:
Defaults:
Description:
%E0
%E1
%E2
%E3
%E4
%E5
&F n
Command:
Values:
Default:
Description:
&F0
&F8
&F9
$F n
Command:
Values:
Default:
Description:
$F0
$F1
Escape Sequence Options
n = 0–5
1 and 4
Modem won't escape.
+++AT<CR> method.
<BREAK>AT<CR> method.
Both +++AT<CR> and <BREAK>AT<CR>
methods.
No OK response to +++AT<CR>.
OK response to +++AT<CR>.
Load Default Configurations
n = 0, 8, or 9
8
Load factory default values from ROM if &F8 was
previously stored; load user default values from
non-volatile memory if &F9 was previously stored.
Read factory default values when &F is issued
(effective only if you store &F8 using &W0).
Read values stored in non-volatile memory when
&F is issued (effective only if you store &F9 using
&W0).
Enable/Disable Auto-Reliable Fallback
Character
n = 0 or 1
0
Do not fall back to non-error correction mode
connect if <CR> is received during handshake.
Fall back to non-error correction mode connect if
<CR> is received during handshake.
35