v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 7942 server," on page 37 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
5105
Processor error.
5120
BIOS checksum error detected.
8601
BMC not responding.
90
IBM System x3610 Type 7942: Problem Determination and Service Guide
Action
1. (Trained service technician only) Reseat the
microprocessor.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. (Trained service technician only)
Microprocessor
b. (Trained service technician only) System
board
1. Start the BIOS Setup Utility program, select Exit,
select Load Default Setting, and then select
Save Changes and Exit.
2. Update the BIOS code:
a. Download the latest version of the BIOS code
from http://www.ibm.com/systems/support/.
b. Update the BIOS code, following the
instructions that come with the update file that
you downloaded.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only) System
board.
1. Update the firmware on the baseboard
management controller.
2. (Trained service technician only) Replace the
system board.