York YAFS012 Manual page 50

Submittal set, affinity & affinity advanced geothermal heat pumps, single and dual capacity, 1/2 thru 1.5/6 nominal tons
Hide thumbs Also See for YAFS012:
Table of Contents

Advertisement

Contractor:
Engineer:
Project Name:
Wiring Schematics cont.
Aurora Base with PSC
Notes
1 - Switch blue a nd red wires for 208V operation.
2 - The blk/wh and gray/wh wi re s are removed when Aux He at is installed
3 - Use manufacturer' s part numb er 19P592-01 (jumper bar assembly) when si ngle source power is
required.
4 - When connected the Auxil iary Heat powers blower and contro ls. Wires a re secured at blower.
5 – Low vol tage wiring CLASS 2.
6 - Refer to FAN SPEED table for factory setti ngs.
7 - Wires p rovided fo r Auxi liary Heat low voltage control. Wires a re secured at blower.
8 - Field installed SPST relay required for dual fuel installation.
Off
On
LED1
1
FP1 – 15
F/30
F
o
o
HP
ECM PWM
P4
R
2
FP2 – 15
F/30
F
o
o
HP
P13
3
RV – B/O
LP
Faul t
LP
4
ACC – Dip 4
FP2
5
ACC – Dip 5
FP2
LED3
6
CC – Dual/Single
FP1
SW1 Test
G
FP1
L – Pulse/Continuous
7
REV
8
Status
Reheat/Normal
REV
SW2
RV – K1
CC2
AURORA BASE
CC – K2
CONTROL™
G
P5
CC Hi – K3
LO
HI
CCG
CC
Fan – K4
FG
F
P11
R
Alarm – K5
JW2 - Alarm
F
Acc – K6
CC
P9
Factory Fan Connection
G
Y1
Fi eld Connections
Fi eld Connections
P2
P1
The rmost at
Tra ditional Thermostat
Y1
1st Sta ge Compre ss or
Dual Fuel Wiring Diagr am
Using Field Installed Relay
Y2
2nd St age Compres sor
O
Re vers ing Va lve
Fos sil Fue l
L
Fault Signa l
Furnac e
C
C
Common
Common
R
R
24 VAC
24 VAC
W
Au xil iary Hea t R ela y
G
G
Fan
Auxil iary
He at Rela y
W
Auxil iary Hea t R ela y
Note 8: Fiel d i ns ta lled SPST dua l f ue l rel ay
(Re quired f or dual f uel i ns ta llat ion)
ABC SW2 Accessory Relay
DESCRIPTION
SW2-4
SW2-5
Cycle with Blower
ON
ON
Cycle with Compressor
OFF
OFF
Water Valve Slow Opening
ON
OFF
Cycle with Comm. T-stat Hum Cmd
OFF
ON
Aurora Timing Events
Event
Normal Mode
Random Start Delay
5 to 80 seconds
Compressor On Delay
5 seconds
Compressor Minimum On Time
2 minutes
Compressor Short Cycle Delay
4 minutes
15 seconds
Blower Off Delay
30 seconds
Faul t Recogn itio n Delay – High Pressure
Less than 1 second
Less than 1 second
Start-Up Bypass – Low Pressure
2 minutes
30 seconds
Faul t Recogn itio n Delay – Low Pressure
30 seconds
30 seconds
Start-Up Bypass – Low Water Coil Limi t
2 minutes
30 seconds
Fault Recogn itio n Delay – Low Water Coil Limit
30 seconds
30 seconds
Faul t Recogn itio n Delay – Condensate Overfl ow
30 seconds
30 seconds
Thermostat Call Recognition Time
2 seconds
Comfort Alert Recog niti on Ti me
90 seconds
90 seconds
Auxi liary Heat Stagi ng Del ay
5 minutes
20 seconds
Emergency Heat Stagi ng Dela y
2 minutes
7.5 seconds
Water Valve Slow Open Delay
90 seconds
90 seconds
The manufacturer works continually to improve its products. As a result, the design and specifi cations of each product at the time of order may be changed without notice. Purchaser's approval of this data set signifi es that the equipment is acceptable under the provisions
of the job specifi cation. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely the manufacturer's opinion or commendation of its products. York and Affi nity are registered
trademarks of Johnson Controls, Inc., and are used with permission.
SD2500AK6
11/22
P.O.:
Unit Tag:
Ext Pump
1/2 hp Total
208-230/60/1
PB1
1
1
1
Violet(7)
Pump
Pump
2
2
Violet(8)
G
LED2
EH1
Y
Hot Water
Blue
Limit Switch
Config
EH2
P3
130°F
C
EH1
DHW
C
Pump
CO
Purple
N/A
Cabinet
HW Switch
(+)
P6
(-)
Blue
R
3
C
2
1
LED5
P7
Optional Internal
G
Com1
Hot Water Generation P ump
P8
LED4
G
Com2
FACTORY SET FAN SPEED
UNIT
STANDARD PSC
12
H
R
R
18
M
22
M
30
M
ABC Board
36
M
Y1
42
M
48
M
Y2
60
M
70
H
O
P1
UNIT
HIGH STATIC PSC
LO
22
M
C
30
M
36
M
R
42
M
48
M
ES
P2
Water Solenoid
= cha ssis
(see Open Loop
Groundwater Systems
section)
LO
R
C
O
Test Mode
G
1 second
Y1
< 1 second
5 seconds
Y2
Traditional
W
Thermostat
2 seconds
DH
AID Tool
2 seconds
Communicating
Thermostat
Green/Yellow
Compr essor
S
C
Blue
R
Cap
Red
Black
Circuit Breaker
Tan(6)
5A
Black(2)
5A
Black(3)
Circuit Breaker
T2
T1
CC
Unit Power Supply
208-230/60/1
L2
L1
G
Black/White(5)
Gray/White(4)
PSC
Blower
Motor
Grn
Brn
Wht
Cap
3 Airflow
NOTE 6
Settings
H
M
L
RB
Black
2
4
5
White(12)
Black(15)
Black
(13)
Violet
(14)
P9
R
F FG CC CCG
CC2
EH1
CC
F
C
P2
ES
LS
ALM
K5-Alarm
ALG
Relay
ACC COM
ACC NO
K6-Acc
Aurora Base Control
ACC NC
Relay
LO
R
C
O/B
G
Y1
Y2
W
DH
P1
Com2
Com1
LED5
LED5
G
G
RS485 NET
R
RS485 NET
C
C
R
-
+
P8
P7
Green(11)
50
Affinity & Affinity Advanced Series
1 - 6 Tons 60Hz
NOTE 2
Bro wn
2
Orange
1
3
PB2
NOTE 1
White
Black
Black(1)
Blue
240V
Red
208V
Tra nsformer
24V
RV
FP1
FP2
LP
HP
Orange
Yellow
Blue
Black
Black
Yellow
Black
Blue
Black
Orange
CC2
CC2
CC2
P5
REVREV FP1 FP1 FP2 FP2 LPS LPSHPSHPS
HI
LO
G
Status
SW1
LED3
G
(ABC)
Test Mode
Faul t
LED1
R
FP1 – 15°F/30°F
FP2 – 15°F/30°F
RV – B/O
Acc – Dip 4
Acc – Dip 5
CC – Dual/Single
L Output Type
Future Use
Config
LED2
Y
RS485 EXP
Y1
G
CC
C
R
-
+
CO
C
EH1
C
EH2
P6
P3
Bro wn(23)
Black(21)
Black(22)
Condensate
Black(20)
Page _____ of _____
NOTE 4
P11
5
4
3
Green
2
1
Yellow
Black/White
P4
C
R
F1-3A
F
PWM
CFM
C
P13
Off
On
1
2
3
4
5
6
7
8
SW2
NOTE 7
To P2 on
Electric Heat
Board

Advertisement

Table of Contents
loading

Table of Contents