York YAFS012 Manual page 44

Submittal set, affinity & affinity advanced geothermal heat pumps, single and dual capacity, 1/2 thru 1.5/6 nominal tons
Hide thumbs Also See for YAFS012:
Table of Contents

Advertisement

Contractor:
Engineer:
Project Name:
Wiring Schematics
Wiring Schematics cont.
Aurora Advanced with ECM and IntelliStart
Slow Flash
1 second on and 1 second off
Fast Flash
100 milliseconds on and 100 milliseconds off
Flash Code
100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating
Fault LED (LED 1, Red)
Normal Mode
Input Fault Lockout
High Pressure Lockout
Low Pressure Lockout
Freeze Detection - FP2
Freeze Detection - FP1
Reserved
Condensate Overflow Lockout
Over/Under Voltage Shutdown
Future Use
Compressor Monitoring
Fault- FP1 Sensor Error
Future Use
Non-Critical AXB Sensor Error
Critical AXB Sensor Error
Alarm - Hot Water
Fault Variable Speed Pump
Future Use
Non-Critical Communication Error
Fault - Critical Communication Error
Alarm - Low Loop Pressure
Fault - Communication ECM Fan Motor Error Flash Code 22
The manufacturer works continually to improve its products. As a result, the design and specifi cations of each product at the time of order may be changed without notice. Purchaser's approval of this data set signifi es that the equipment is acceptable under the provisions
of the job specifi cation. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely the manufacturer's opinion or commendation of its products. York and Affi nity are registered
trademarks of Johnson Controls, Inc., and are used with permission.
SD2500AK6
11/22
P.O.:
Unit Tag:
AXB BOARD
Aurora LED Flash Codes
Random Start Delay (Alternating Colors)
OFF
Status LED (LED1, Green)
Flash Code 1
Configuration LED (LED 2, Yellow)
Flash Code 2
Fault LED (LED 3, Red)
Flash Code 3
Configuration LED (LED 2, Yellow)
Flash Code 4
No Software Overide
Flash Code 5
DIP Switch Overide
Flash Code 6
Status LED (LED 3, Green)
Flash Code 7
Normal Mode
Flash Code 8
Control is Non - Functional
Flash Code 9
Test Mode
Flash Code 10
Lockout Active
Flash Code 11
Dehumidification Mode
Flash Code 12
Future Use
Flash Code 13
Future Use
Flash Code 14
Load Shed
Flash Code 15
ESD
Flash Code 16
Future Use
Flash Code 17
Fault LED (LED 1, Red) Cont.
Flash Code 18
Alarm - Home Automation 1
Flash Code 19
Alarm - Home Automation 2
Flash Code 21
Fault - EEV Error
Fast Flash
Fast Flash
Fast Flash
OFF
Slow Flash
ON
OFF
Slow Flash
Fast Flash
Flash Code 2
Flash Code 3
Flash Code 4
Flash Code 5
Flash Code 6
Flash Code 7
Flash Code 23
Flash Code 24
Flash Code 25
44
Affinity & Affinity Advanced Series
1 - 6 Tons 60Hz
Page _____ of _____

Advertisement

Table of Contents
loading

Table of Contents