OfficeServ 7100
TECHNICAL MANUAL
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPEAKER
ACTION
1. Press TRANSFER 835.
Display shows the first option. Press UP or
DOWN key to select MGI3 or MGI2
OR
2. Press RIGHT soft key to move cursor. Press
UP or DOWN key to select an parameter.
3. Press RIGHT soft key to enter data and move
cursor.
4. Press UP or DOWN key to select an option
OR
Press TRANSFER to store and exit
OR
Press SPEAKER to store and advance to next
MMC.
DEFAULT DATA:
MMC: 835
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to store data and advance to next MMC
AUDIO CODEC: G.729A
ECHO CANCEL: ENABLE
SILENCE SUP: ENABLE
IN FILTER: ENABLE
OUT FILTER: ENABLE
INPUT GAIN: 31
VOICE VOL: 31
JITTER OPT: 04
MIN JITTER: 030ms
MAX JITTER: 150ms(MGI3)
FAX ECM: ENABLE
MAX FAX CNT: 02
DTMF TYPE: OUTBAND(MGI3)
TOS DATA: 00000
FAX RETRY: 0
RTP CHECK TIME: 5 seconds
USE T38711: ENABLE
PROGRAMMING
PART 2 APRIL 2007
DISPLAY
AUDIO CODEC
G.729A
AUDIO CODEC
G.729A
AUDIO CODEC
G.729A
MGI3:AUDIO CODEC
G.729