number to 1001, then save &close. This will load the Prompt screen again. Make
sure the language is set to Spanish. Enter an extension number in the upper
right text box and click call to have the system call to prep for recording. Locate
the page with the 1001 prompt and click the number 1001. The system will
prompt (in Spanish) through the recording process. Once finished hang up.
We will now go back to the Day Main Menu block to set up the option to select
Spanish. In order to activate the Spanish Menu we need to set the Language
register to Spanish if the user requests it. We do this by changing the Input
Processor Operating Parameters on the General screen of the Day Main Menu.
Take INPUT from is set to ENTRY, which means DTMF input from the caller. We
need to change Store INPUT in to LANG.
Now change the prompt from 1001 to 1010, which we will record as the "please
press 2 for Spanish or stay on the line for English" prompt. Making this change
allows us to use 1001 for both the English and Spanish Menu, which simplifies
changes in the future.
On the Menu Input Processor we will Clear the following Event Pointers: 5000, *,
6, 8, 0, ???, ????, ???, and ????. We will insert new Event Pointers that will point
to the correct Menus. Single digits 1 and 2 will go to the Day Main 2 Menu.
NO-ENTRY will be set to translate to 1. This means that users can press 1 or
remain on the line to get to the English menu.
Programming:
On the Language screen of System Parameters set Select First Language to
English, American.
Set Select Second Language to Spanish, Castillian.
Set the Key Code for English to 1.
Set the Key Code for Spanish to 2 and click Save.
Open the Day Main Menu block and click Copy.
Enter the Label Name as Day Main 2 and click Save
Close the Day Main 2 Menu and open the Day Main Menu again.
On the General screen set Store INPUT in to LANG.
Change Prompt 1 from 1001 to 1010 and click Save.
On the Menu Input Processor screen press the Clear button to the right of the
5000 Event Pointer.
On the Menu Input Processor screen press the Clear button to the right of the *
Event Pointer.