Air Conditioner; Zoning Control; Pureair S - Lennox S40 Installation And Setup Manual

Smart thermostat
Hide thumbs Also See for S40:
Table of Contents

Advertisement

Air Conditioner

Table 10. Air Conditioner Parameters
Parameter
Description
This screen provides information concerning language supported,
equipment type name, unit model number, unit serial number, unit
nominal capacity, number of cooling stages, cooling capacity by
stage, control software revision, control model number, control
serial number, control hardware revision, outdoor air temp sensor,
About
protocol revision number, device product level, 24VAC average
power consumption, 24VAC peak power consumption, line voltage
average power consumption, line voltage peak power consumption,
outdoor inverter model number, outdoor inverter firmware version,
outdoor fan RPM profile, unit code, compatible devices list,
application code memory size and micro-controller part number.
This feature prevents the compressor from being short cycled
any time the compressor is turned "OFF". The range is 60 -
300 seconds. Default is 300 seconds and with an incremental
adjustment of 60 seconds. When the system initiates a compressor
Compressor Short
short cycle delay, the outdoor unit control's seven segment display
Cycle Delay
will show the delay in minutes from 1 to 5 minutes. The sequence is
time (minutes) remaining and a dash, and will repeat that cycle (5,
4, 3, 2 and 1) until the count down is complete. If the delay timer is
change for example to 180 seconds, then the countdown will start
at 3 (minutes).
Dehumidification airflow = "HUMID" Mode CFM table value for a
given thermostat demand + dehumidification adjustment adder
Dehum Airflow
(High Normal Cooling Airflow CFM x Dehumidification Airflow
Adjustment Adder
Adjustment Adder in percentage. Both these values are in the
installer set up under System Device/Air Conditioner/High Normal
Cooling Airflow).
A unique name can be assigned to this component. Name can be
Equipment Name
up to 29 characters. Name can consist of letters, numbers, special
characters and spaces.
High Normal
The range is 450 - 2150 CFM. Default is dependent on unit
Cooling Airflow
capacity with an incremental adjustment of 25 CFM.
(Lennox Variable
Thermostat values shown are defaults. This value can be adjusted
Capacity Air
up or down to meet each application requirements.
Conditioners Only)
Low Normal
The range is 450 - 2150 CFM. Default is dependent on unit
Cooling Airflow
capacity with an incremental adjustment of 25 CFM.
(Lennox Variable
Thermostat values shown are defaults. This value can be adjusted
Capacity Air
up or down to meet each application requirements.
Conditioners Only)
Any installer modifications under the air conditioner tab will be
Reset Air
reset back to the factory defaults if the reset air conditioner option
Conditioner
is used.
Table 11. Zoning Control Parameters
Parameter
Description
This provides information on unit code, language supported,
equipment type name, control software revision, control model
number, control serial number, control hardware revision, protocol
revision number, device product level, 24VAC average power
About
consumption, 24VAC peak power consumption, compatible devices
list, application code memory size, micro-controller part number,
max number of zones, supported damper types, number of damper
positions, zone temp sensor 1, zone temp sensor 2, zone temp
sensor 3 and zone temp sensor 4.
A unique name can be assigned to this component. Name can be
Equipment Name
up to 29 characters. Name can consist of letters, numbers, special
characters and spaces.
Zones 1 through
Allows adjustment to temperature reading displayed on zone
4 Temp Reading
thermostat.
Calibration
Any installer modifications under the zoning control tab will be reset
Reset Zoning
back to the factory defaults if the reset zoning control option is
Control
used.
Table 12. PureAir S Parameters
Parameter
Description
Equipment
PureAir Filter
Default: ON. Options are either ON or OFF.
This parameter turns on and off the filter life and UV lamp life
reporting. When set to off, the control will continue to calculate
the remaining filter life through continuous sampling, but will not
use filter tests to determine filter life. The control will:
• Perform a filter calibration upon indication of a filter change
regardless of the value of this parameter.
Dirty Filter
• Perform a UVA lamp calibration upon indication of a lamp
Detection and UV
change regardless of the value of this parameter.
Life Detection
• Calculate UVA lamp life remaining regardless of the value of
this parameter.
Alarms 504 and 503 will not be sent while this parameter is set
to "Off"
The Diagnostics screen on the thermostat will continue to show
values for both filter life and UV lamp life regardless of the value
of this parameter.