Air Temperature Sensor Connections; Mag-Mount Led And Installation; Installation - Lennox iComfort E30 Installation And Setup Manual

Smart thermostat
Hide thumbs Also See for iComfort E30:
Table of Contents

Advertisement

Air Handler Heat Stages
Label
(Position)
0
No Electric Heat
1
1
2
2
(default)
3
3
If jumper is missing, setting defaults to single stage. Changing jumper position after power-up requires recommission for the change to be recognized.
a
t
s
C
ir
EmpEraturE
Ensor
onnECtions
Label
Function / Description
Show ambient temperatures (optional if weather feed is
acceptable; use X2658 Outdoor Sensor - 2 terminals).
Outdoor
Wiring distance between the thermostat and the outdoor
Air Sensor
temperature sensor can not exceed 200 feet (61 m) when
wired with 18 #AWG thermostat wire.
Optional for diagnostics of indoor air; use 88K38 Discharge
Air Sensor - 2 terminals.
Discharge
Wiring distance between the furnace or air handler control
Air Sensor
module and the discharge air sensor should not exceed 10
feet (3 meters) when wired with 18 #AWG thermostat wire.
0
100%
50%, 100%
33.5%, 66.5%, 100%
Table 6. Sensors
Table 5. Heat Stage Jumpers
Furnace Heat Stages
1
100%
1
100%
2
70%, 100%
2
70%, 100%

Mag-Mount LED and Installation

Magnets located in this product have far-reaching and strong magnetic fields.
They could damage TVs and laptops, computer hard drives, credit and ATM
cards, data storage media, mechanical watches, hearing aids and speakers.
Keep HD Display and Mag-Mount away from devices and objects that could be
damaged by strong magnetic fields.
i
nstallation
ACCESS
COVER
ACCESS COVER MAKE SURE THAT IT
IS SEATED PROPERLY. NOT DOING
SO WILL CAUSE CONNECTION
8
Heat Pump Stages
1
1
3
3
CAUTION
MAG-MOUNT WITHOUT
ACCESS COVER
WHEN REINSTALLING
ISSUES.
100%
100%
70%, 100%
70%, 100%
WALL PLATE (USE IS
OPTIONAL)