Measuring Ranges - Siemens 3RS2 Manual

Monitoring and control devices temperature monitoring relay
Table of Contents

Advertisement

Thermocouples
• Type J
• Type K
• Type T
• Type E
• Type N
• Type S
• Type R
• Type B
Details are provided in Chapter Thermocouples (Page 67).
5.8

Measuring ranges

Measuring range of resistance sensors
Sensor type
Short-circuit moni‐
toring
Pt100
Yes
Pt1000
Yes
KTY83-110
Yes
KTY84
Yes
NTC 1)
Yes
1) NTC type: B57227-K333-A1 (100 °C: 1.8 kΩ; 25 °C 32.762 kΩ).
Measuring ranges of thermocouples
Thermocouple type
Short-circuit moni‐
toring
J
No
K
No
T
No
E
No
N
No
S
No
R
No
B
No
3RS2 temperature monitoring relay
Equipment Manual, 02/2022, A5E42462552002A/RS-AB/002
Sensor wire break monitor‐
ing
Yes
Yes
Yes
Yes
No
Sensor wire break monitor‐
ing
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
5.8 Measuring ranges
Measuring range in
Measuring range in
°C
°F
-50 ... +750
-58 ... +1382
-50 ... +500
-58 ... +932
-50 ... +175
-58 ... +347
-40 ... +300
-40 ... +572
+80 ... +160
+176 ... +320
Measuring range in
Measuring range in
°C
°F
-99 ... +1200
-146.2 ... +2192
-99 ...+1350
-146.2 ... +2462
-99 ... +400
-146.2 ... +752
-99 ... +999
-146.2 ... +1830.2
-99 ... +1300
-146.2 ... +2372
0 ... +1750
+32 ... +3182
0 ... +1750
+32 ... +3182
+400 ... +1800
+752 ... +3272
Digital devices