SECURE TO CAVITY
1
2
3
Loosely fit 2 x side fixing screws.
If needed, adjust the dishwasher within
the cavity before tightly securing in
place. Replace the screw covers.
Secure to benchtop using 2 x screws
if possible.
PLUMBING & ELECTRICAL CONNECTION
Ø1 1/2" (38MM) STANDPIPE INSTALLATION
1
2
3
4
Install the drain hose support to the
back wall, as close to the underside of
the countertop as possible. Refer to
'Plumbing & electrical considerations' for
minimum install heights.
Pull the hose through the support guide
and rest in standpipe.
Ensure the drain hose does not extend
into water retained in the trap; an air gap
is required to prevent waste water from
siphoning back into the tub.
Connect the inlet hose to tap and
handtighten into place. Using a spanner
or pliers, turn a further 180° to secure.
Avoiding over tightening.
Do not turn water supply on. The
dishwasher must be powered on for the
flood protection feature to be enabled.
Plug product in.
Non-hardwired installs only.
17