Power Off/On the machine.
048-326
Cause: Interface Module/Interface Cooling Module communication failure or
connection failure
Remedy: Perform the following:
Check the connection between the Interface Module/Interface Cooling Module and
the connected finishing device or devices.
Fully clear any jams between the Interface Module/Interface Cooling Module and
the connection finishing device or devices.
Ensure all jam clearance handles/levers are returned to their closed positions.
After clearing all jams, remove any ejected paper from the finishing output area.
Power Off/On the machine.
048-327
Cause: Interface Module/Interface Cooling Module communication failure or
connection failure
Remedy: Perform the following:
Check the connection between the Interface Module/Interface Cooling Module and
the connected finishing device or devices.
Fully clear any jams between the Interface Module/Interface Cooling Module and
the connection finishing device or devices.
Ensure all jam clearance handles/levers are returned to their closed positions.
After clearing all jams, remove any ejected paper from the finishing output area.
Power Off/On the machine.
048-900
Cause: Paper jam:
A jam occurred during feeding.
A jam notification is displayed on the UI.
Remedy: Perform the following:
1.
Open the Interface Module/Interface Cooling Module front door.
2.
Carefully remove all sheets and paper scraps from the jam clearance areas.
3.
Close the front door. Verify the paper used is within the approved paper
specifications.
048-901
Cause: Paper jam:
A jam occurred during feeding.
A jam notification is displayed on the UI.
Remedy: Perform the following:
®