3. Air piping

WARNING :
To protect against personal injury due to abrupt start of the machine, conduct maintenance works with
the power turned off.
(1) Air piping drawing
Perform the piping while referring to the piping drawing below.
Rotary air cylinder
ø4 R =0.7 m
Intermediate latch drive
solenoid valve
ø4 R =0.7 m
ø4 R =1 m
ø6 R =0.8 m
ø4 R =1 m
Thread tension release
solenoid valve
ø6 R =1 m
Presser lifter solenoid valve
Adjustment knob
Air regulator