Fireplace Installation, Operation, And Maintenance Notices - Superior Fireplaces DRT4240DEN-B Installation And Operation Instruction Manual

Direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRT4200 Series Direct-Vent Gas Fireplaces
APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES
Improper installation, adjustment, alteration, service or maintenance can cause injury or
property damage. Refer to this manual. For assistance or additional information consult a
qualified installer, service agency or the gas supplier.
Une installation, un réglage,une modification, une réparation ou un entretien mal effectué
peut causer des dommages matériels ou des blessures. Voir la notice de l'utilisateur qui
accompagne l'appareil. Pour de l'aide ou des renseignements supplémentaires, consultez
un installateur, un technicien agréé ou le fournisseur de gaz.
Only trim kit(s) supplied by the manufacturer shall be used in the installation of this fireplace.
These appliances must not be connected to a chimney or flue serving a separate solid fuel
burning appliance.
Any change to this appliance and/or its operating controls is dangerous. Improper installation
or use of this appliance can cause serious injury or death from fire, burns, explosion or
carbon monoxide poisoning.
CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to
the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air
immediately. Turn off the gas supply to the appliance and have it serviced by a qualified
professional, as it may not be operating correctly. Some people are more affected by carbon
monoxide than others, including pregnant women, people with heart or lung disease or
anemia, those under the influence of alcohol, and those at high altitudes.
Turn off gas and electrical power to the appliance and allow it to cool before cleaning or
servicing the appliance.
If the barrier becomes damaged, the barrier shall be replaced with the manufacturer's barrier
for this appliance.
For use with barrier(s) Part No(s). F1840 (40" Models), and F1903 (45" Models). Follow
installation instructions.
Reinstall any barrier removed before operating the appliance. The barrier is designed to
reduce the risk of burns from hot glass. Do not operate the appliance without the barrier
installed.
6
Seules des portes certifiées pour cet appareil doivent être utilisées.
Si l'écran est endommagé, il doit être remplacé par celui fournit par le fabricant de cet
appareil.
WARNING
AVERTISSEMENT
General Information
900636-01, 01/2017

Advertisement

Table of Contents
loading

Table of Contents