Superior Fireplaces DRT4240DEN-B Installation And Operation Instruction Manual page 38

Direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRT4200 Series Direct-Vent Gas Fireplaces
4. Connect the black power supply wire to the lower
5. Connect the ground supply wire to the pigtail lead
6. After the wiring is complete, replace the cover plate.
Electronic models of these appliances are equipped with a three-prong (grounding)
plug utilized in connecting the electronic components to the junction box in the lower
compartment. This grounding plug provides protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. DO NOT cut or remove the
grounding prong from the plug.
38
outlet's black and red pigtail lead (Figures 30 and
31). Connect the white power supply wire to the
outlet's common terminal.
attached to the outlet's green ground screw. Restrain
the inlet power lead per NEC or local codes.
Figure 30 - Wiring Diagram—Junction Box
Green
White
Black
Tab
Intact
Tab Intact
Hot Side of
Receptacle
Green
Neutral
Ground
Side of
Screw
Receptacle
WARNING
Installation
900636-01, 01/2017
Ground - Green
Neutral - White
120 VAC - Black
(Power
Junction Box
Supply
Unswitched)
Red
J-BOX / RECEPTACLE
WIRING 120V, 60HZ, 1PH
Field Wired
Factory Wired

Advertisement