MAINTENANCE AND SERVICE (CONT'D)
• Check Vent System
The fireplace and venting system should be inspected before
initial use and at least annually by a qualified service person.
Inspect the external vent cap on a regular basis to make sure
that no debris is interfering with the air flow.
Glass Cleaning
Clean the glass before use and two or three times each heating
season. During start-up condensation (which is normal) forms on
the inside of the glass and causes lint, dust and other airborne
particles to cling to the glass surface. Also initial paint curing may
deposit a slight film on the glass. Use a non-abrasive household
cleaner and warm water (we recommend gas fireplace glass
cleaner).
General Glass Information
Do not operate fireplace with the glass front removed,
cracked or broken.
Only glass approved for use by the manufacturer in fireplace may
be used for replacement. The glass replacement should be done
by a licensed or qualified service person.
1.
The use of substitute glass will void all product warranties.
2.
Care must be taken to avoid breakage of the glass.
3.
Under no circumstances should this fireplace be operated
without the glass front or with a broken glass front.
Replacement of the glass (with gasket) as supplied by
the manufacturer should be done by a qualified service
person.
4.
Do not abuse the glass by striking or hitting it.
Do not use Ammonia based or abrasive cleaners on glass.
Do not attempt to clean glass when glass is hot.
Page 56
WARNING
WARNING
WARNING
Glass Door and Barrier Screen Removal and Replacement
Refer to page 53 for removal of the barrier screen and glass door
assemblies.
Refer to the Parts View and Parts List on pages 50 and 51 to
identify replacement parts such as the barrier screen and glass
door assemblies.
Glass Door Installation
Refer to Figure 98 to install the glass door assembly. Because
of the width of the door assembly, it is recommended that two
people install it. Hold the door at an angle so the bottom is about
8 inches from the fireplace face. Engage the top slots in to door
frame with the tabs located at the top of the firebox. Gently pivot
the door inward to align the four bullet catches across the bottom
of the door frame. Once the bullet pins are aligned with the spring
catches on the door frame, push the bottom of the door inward to
engage the spring catches with the bullet pins.
Barrier Installation
The barrier screen assembly is installed onto the glass door
assembly without fasteners. The top flange of the barrier
engages the top of the door frame and the bottom flange. The
bottom flange on the barrier will be inserted between the glass
door frame across the bottom. Adjust the barrier left to right to
center it.