ELECTRICAL CONNECTIONS (CONT'D)
Once the Junction box has been installed with the receptacle
outlets facing inward towards the fireplace, locate the 3-prong
power cord from the control module and plug into the receptical.
The fireplace is supplied with a User Interface wall box that must
be installed in a standard plastic outlet box (not provided). A low
voltage orange or blue box is recommended. The user interface
wall box must be placed in the wall within ten feet from the right
side of the fireplace. A 10ft. battery and user interface extension
wire harness is supplied.
The red and black battery extension harness is connected to
the red and black mating connector pre-installed on the control
module. The mating connector can be located inside the fireplace
near the gas valve. See Figure 22.
Locate and install the 5/8in diameter plastic snap-in grommet
over the low-voltage battery and interface extension harnesses at
the right side of the fireplace. Snap the grommet into the hole in
the side of the fireplace just under the access panel opening. See
Figure 22.
Run the extension wiring to the user interface wall box and
connect the white connector to the remote receiver battery box.
Install the battery box into the wall outlet box, then install the
white remote cover supplied with the provided screws.
HAND BENT
FLANGE
NOTE: OUTER ACCESS DOOR REMOVED. REPLACE AFTER ALL
WIRE AND GAS CONNECTIONS HAVE BEEN MADE
41368-0-0120
WIRE
GROMMET
USER INTERFACE HARNESS
& BATTERY EXTENSION
HARNESS
CONNECT TO THE USER INTERFACE/BATTERY
HOLDER. MUST BE INSTALLED IN A WALL
JUNCTION BOX (ORANGE LOW VOLTAGE OR
BLUE BOX RECOMMENDED)