Checking Manifold Pressures
Both Propane and Natural Gas valves have a built-in pressure
regulator in the gas valve. Natural Gas models will have a
manifold pressure of approximately 3.5-in w.c. (.871 kPa) at the
valve outlet with the inlet pressure to the valve from a minimum
of 4.5-in w.c. (1.120 kPa) for the purpose of input adjustment to
a maximum of 14.0-in w.c. (3.484 kPa). Propane Gas models will
have a manifold pressure approximately 10.0-in w.c. (2.49 kPa)
at the valve outlet with the inlet pressure to the valve from a
minimum of 10.8-in w.c. (2.68 kPa) for the purpose of input
adjustment to a maximum of 14.0-in w.c. (3.484 kPa).
If one of the procedures results in pressures in excess of
1/2 psig (14-in w.c.) (3.5 kPa) on the fireplace gas valve, it
will result in a hazardous condition.
GAS VALVE
INLET
PRESSURE
TAP
41368-0-0120
GAS SUPPLY (CONT'D)
CAUTION
OUTLET
PRESSURE
TAP
Figure 17
Gas Line Connection
Remove the access panel from the right side of the fireplace
shown in Figure 18 to access the gas valve, gas flex line,
junction box, and system wiring.
Attach the gas flex line to the pre-installed gas line. Refer to the
Gas Supply section in this manual for details on the installation
requirements for the gas supply line.
NAILING FLANGE
ACCESS PANEL
GAS LINE
ACCESS
14 5/8
"
14
REMOTE WALL BOX
WIRING EXIT POINT
JUNCTION BOX
Figure 18
Page 17