ALARM

The red LED will flash and the alarm will sound when dangerous levels of gas are detected. The
detector will continue to alarm until the gas clears or the "MUTE" switch is pressed. (See

Procedures To Take During An Alarm).

PROCEDURES TO TAKE DURING AN ALARM
1. Turn off all gas appliances (stove, heaters, furnace). Extinguish all flames and smoking
material. Evacuate - leave doors and windows open.
2. Turn off the LP gas tank valve.
3. Determine and repair the source of the leak. Contact a qualified technician for help if
necessary.
#
CAUTION: Do not re-enter until the problem is corrected.

ALARM MUTE

This feature is activated by pressing the TEST/MUTE button when the detector is in alarm.
1. The red LED will continue to flash and the alarm will beep every thirty seconds until the gas
level has dropped to a safe level.
2. The LED will flash green until the end of the mute cycle.
3. If dangerous gas levels return before the end of the mute cycle, the alarm will beep four times
and return to #1.
4. After two minutes, the detector will return to normal operation (solid green) or resound the
alarm if dangerous levels of gas remain in the area.

Malfunction Alarm

The microprocessor will activate the malfunction alarm when it detects a fault in the detectors
operation. The LED will alternately flash red and green, while the sounder beeps twice every
fifteen seconds. The mute switch will not function. Remove the detector immediately and return it
for repair or replacement.

Low Power Operation

This detector will operate normally down to 7-volt DC. Do not operate this detector below 7-volt
DC. Additional information is supplied in a manual published by the manufacturer.
y
WARNING: Limitations of propane/methane gas detectors:
This detector will not work without power. Examples causing no power
are: an open circuit breaker, a faulty power line connection, a blown or
missing fuse.
This detector will only indicate the presence of propane or methane gas at
the sensor. Explosive gas may be present in other areas.
This detector may not be heard. The alarm loudness is designed to meet or
exceed regulatory standards, however, the alarm may not be heard if
detectors are located in remote locations or behind closed doors. The alarm
may not be heard by persons who are hard of hearing.
This detector is not a smoke or fire detector. It is not suitable as a smoke or
fire detector.
This detector is not suitable for installation in hazardous areas as defined
in the national electrical code.