  • Page 1 GEMÜ 202 Electrically operated solenoid valve Operating instructions further information webcode: GW-202...
  • Page 2 All rights including copyrights or industrial property rights are expressly reserved. Keep the document for future reference. © GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG 09.05.2022 GEMÜ 202 2 / 20 www.gemu-group.com...
  • Page 3: Table Of Contents

    14 Troubleshooting ..........15 Removal from piping ..........16 Disposal .............. 17 Returns ..............18 Declaration of Incorporation according to 2006/42/EC (Machinery Directive) ....... 19 Declaration of conformity according to 2014/68/ EU (Pressure Equipment Directive) ...... www.gemu-group.com 3 / 20 GEMÜ 202...
  • Page 4: General Information

    Lists Potentially dangerous situation! 1.3 Definition of terms ▶ Non-observance can cause death or severe injury. Working medium The medium that flows through the GEMÜ product. CAUTION Potentially dangerous situation! ▶ Non-observance can cause moderate to light injury. NOTICE Potentially dangerous situation! ▶...
  • Page 5: Safety Information

    1. Transport and store the product correctly. 3.2 Description 2. Do not paint the bolts and plastic parts of the product. The GEMÜ 202 directly controlled 2/2-way solenoid valve has 3. Carry out installation and commissioning using trained a completely plastic encapsulated coil. The armature is personnel.
  • Page 6: Function

    Traceability number Consecutive number The month of manufacture is encoded in the traceability num- ber and can be obtained from GEMÜ. The product was manu- factured in Germany. The operating pressure stated on the product label applies to a media temperature of 20 °C. The product can be used up to the maximum stated media temperature.
  • Page 7: Correct Use

    The product is designed for installation in piping systems and for controlling a working medium. 1. Use the product in accordance with the technical data. 2. Protect the product from direct weathering. www.gemu-group.com 7 / 20 GEMÜ 202...
  • Page 8: Order Data

    6 Seal material 7 Control function Normally closed (NC) 8 Voltage 230 V 9 Frequency 50/60 50 - 60 Hz 10 Special specification Without 11 CONEXO Integrated RFID chip for electronic identification and traceability GEMÜ 202 8 / 20 www.gemu-group.com...
  • Page 9: Technical Data

    EMC Directive: 2014/30/EU Technical standards used: EN 55011:1991 (150 kHz to 30 MHz) EN 55014:1993 (148.5 kHz to 30 MHz) 6.5 Mechanical data Protection class: IP 65 Weight: 0.21 kg Cable gland: PG 11 www.gemu-group.com 9 / 20 GEMÜ 202...
  • Page 10: Dimensions

    A = 60 (DC) / 67 (AC) Dimensions in mm 7.2 Body dimensions 7.2.1 Threaded socket (code 1) ø 68 DN 10: G = G3/8 ø 68 DN 15: G = G1/2 Dimensions in mm GEMÜ 202 10 / 20 www.gemu-group.com...
  • Page 11 7 Dimensions 7.2.2 Solvent cement socket (code 2) ø68 ød DN 10: ød = 16 ø68 DN 15: ød = 20 Dimensions in mm 7.3 Mounting dimensions M5 (9 mm depth) Dimensions in mm www.gemu-group.com 11 / 20 GEMÜ 202...
  • Page 12: Manufacturer's Information

    Do not exceed the permissible temperature of the work- chapter "Technical data"). ● ing medium. 4. Do not store solvents, chemicals, acids, fuels or similar fluids in the same room as GEMÜ products and their spare 9.1 Installation with solvent cement sockets parts. CAUTION 8.4 Scope of delivery...
  • Page 13: Electrical Connection

    12 Operation ibly clicks in position. During normal operation there is no need for adjustments at 4. Ensure that the cable is not caught. the valve. 5. Tighten the locking screw on the plug. www.gemu-group.com 13 / 20 GEMÜ 202...
  • Page 14: Inspection And Maintenance

    3. Shut off plant or plant component. 4. Secure plant or plant component against recommission- ing. 5. Depressurize the plant or plant component. 6. Actuate GEMÜ products which are always in the same po- sition four times a year. 13.1 Cleaning the product CAUTION Foreign matter ▶...
  • Page 15: Troubleshooting

    Check connection of plug and correct if necessary Operating pressure too high Check operating pressure, reduce if ne- cessary Armature blocked Replace solenoid valve Solenoid valve leaking Valve seat leaking Replace solenoid valve PTFE bellows leaking Replace solenoid valve www.gemu-group.com 15 / 20 GEMÜ 202...
  • Page 16: Removal From Piping

    The equipment is subject to pressure! goods can be processed only when this note is completed. If ▶ Risk of severe injury or death. no return delivery note is included with the product, GEMÜ Depressurize the plant. ● cannot process credits or repair work but will dispose of the Completely drain the plant.
  • Page 17: Declaration Of Incorporation According To 2006/42/Ec (Machinery Directive)

    18 Declaration of Incorporation according to 2006/42/EC (Machinery Directive) Declaration of Incorporation according to the EC Machinery Directive 2006/42/EC, Annex II, 1.B for partly completed machinery GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG Fritz-Müller-Straße 6-8 74653 Ingelfingen-Criesbach, Germany declare that the following product Make: GEMÜ...
  • Page 18: Declaration Of Conformity According To 2014/68/Eu (Pressure Equipment Directive)

    EN 1983, AD 2000 Note for products with a nominal size ≤ DN 25: The products are developed and produced according to GEMÜ process instructions and quality standards which comply with the requirements of ISO 9001 and ISO 14001. According to Article 4, Paragraph 3 of the Pressure Equipment Directive 2014/68/EU these products must not be identified by a CE-label.
  • Page 19 GEMÜ 202 19 / 20 www.gemu-group.com...
  • Page 20 GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG Fritz-Müller-Straße 6-8, 74653 Ingelfingen-Criesbach, Germany Subject to alteration Phone +49 (0) 7940 1230 · info@gemue.de www.gemu-group.com 05.2022 | 88593450...

This manual is also suitable for: