(2) Check if it is caused by an operation miss or is a failure.
To check if the cause of failure of Port1 is an operation miss or not, analyze the Drive
Log of Port0.
1. In [REDUNDANT] of Port-0, find a log of "Fail this drive" message by PgUp and
2. If no message of "Fail this drive" message, it is judged that the second HDD is
(3) How to change the status to OFF LINE
Release the status of "Fail", using the menu of [Force OFFLINE]. This HDD is not
necessary to be repaired.
PORTEGE M400 Maintenance Manual (960-541)
Get user manuals:
See SafeManuals.com
PgDn key.
removed without the operation of removal by TOSHIBA RAID console and
installed again.