Table 8-10 Diagnostic Messages - Siemens GCP5000 Instruction & Installation Manual

Grade crossing predictor for electrified territory (gce)
Table of Contents

Advertisement

DETAILED CASE AND MODULE DESCRIPTION
_________________________________________________________________________________________________________
If there are diagnostic messages present the display will scroll round and show which DIAG
messages are present.
Diag Text
1CAL
2CAL
ICAL
1FRQ
2FRQ
IFRQ
1OOS
2OOS
IOOS
1COD
2COD
1RCV
2RCV
IXMT
PXMT
PXFR
RECV
UCFG
SIG-00-22-02
Version: B.1

Table 8-10 Diagnostic Messages

Description
Calibration required for RX1
Calibration required for RX2
Calibration required for Island
Frequency not set for RX1
Frequency not set for RX2
Frequency not set for the island
RX1 is out of service
RX2 is out of service
Island out of service
RX1 receiving unexpected code
RX2 receiving unexpected code
RX1 receiver unhealthy
RX2 receiver unhealthy
Island transmitter error
PSO transmitter error
PSO frequency error
PSO recovering from an unhealthy state
No comms to the CPU module
8-20
JUNE 2022 (Revised September 2022)