USER INTERFACE

Mode Select Screen
Cutting
Press to Select
Choose between four available modes:
Cut – For cutting operations on a solid workpiece.
Mark – For discoloring or slight removal of material. Can
be used to add part numbers, bend lines, drill marks, or
many other surface modifications.
Grid – For cutting operations on a non-continuous
workpiece.
Gouge – For removing material from a workpiece
(removing a weld).
Upon power up the machine will default to the last used mode and
workpoint, if this is the first power up the machine will default to a
cut mode and the maximum work point on the display. Pressing
the "HOME" button will allow the user to select between the 4
different modes of operations. These modes can be selected by
depressing the Menu Control Knob/Button of the desired
highlighted box. Use of the User Interface is locked out should the
machine be connected to an HMI control via the Ethernet port on
the back of the machine.
Press to Select
B-3
I F
G
U
R
E
B
4 .
A
C
125
Output Current
60
0
The Active Mode Screen will display the following information:
Active Mode Icon- The currently selected mode icon will be
displayed here. To select a new mode, press the HOME button and
the desired mode, or utilize the HMI. When being controlled
remotely via the System HMI, the mode icon will be grayed out.
Output Current – Turn the control knob to adjust the desired
output current, or update with the HMI. While cutting, the screen
will display the actual cutting current in Amps. Output current
range is dependent on the mode selected..
Plasma Gas Pressure- The plasma gas pressure is displayed on a
linear scale, with the center of the green range as the
recommended plasma gas pressure based on the selected mode.
Use the plasma gas regulator knob on the front of the machine to
adjust the plasma gas pressure. It is recommended that this be
done only while gas is flowing. Hold the PURGE button to the right
of the control knob while pulling out and then turning the plasma
gas regulator knob to adjust the pressure to the desired setting. A
purge command can also be initiated via the HMI.
Shield Gas Pressure- The shield gas pressure is also displayed on
a linear scale, with the center of the green range as recommended
shield gas pressure based on the selected mode. Use the shield
gas regulator knob on the front of the machine to adjust the shield
gas pressure. It is recommended that this be done only while gas
is flowing. Hold the PURGE button while pulling out and then
turning the shield gas regulator knob to adjust the pressure to the
desired setting. A purge command can also be initiated via the
HMI.