Lincoln Electric FlexCut 200 CE Operator's Manual page 42

Hide thumbs Also See for FlexCut 200 CE:
Table of Contents

Advertisement

®
FlexCut
200 CE
200 Amps - Aluminum
Imperial*
Plasma
Material Thickness
Pressure
(ga)
(in)
(psi)
3/16
0.188
1/4
0.250
3/8
0.375
1/2
0.500
5/8
0.625
69
3/4
0.750
1
1.000
1 1/4
1.250
1 1/2
1.500
Metric*
Plasma
Material Thickness
Pressure
(mm)
(BAR)
4
6
10
12
16
4.76
20
25
32
38
Marking
Material
Plasma
All Thicknesses
(Plasma) (Shield) Amps
(psi)
Air
Air
18
25
* Use an arc transfer height (ignition height) of .200" (5.1
mm) for cutting and .100" (2.5 mm) for marking.
Shield
Arc
Travel
Pressure
Voltage
Speed
(psi)
(ipm)
150
220
152
190
156
135
160
105
35
164
90
169
65
177
40
189
20
196
12
Shield
Arc
Travel
Pressure
Voltage
Speed
(BAR)
(mm/min)
149
5975
152
5000
157
3325
159
2825
2.41
164
2250
170
1550
176
1050
189
500
196
300
Shield
(BAR)
(psi)
(BAR)
1.72
35
2.41
Explosion Hazard
Do not cut Aluminum over water tables
Cutting
Pierce
Pierce
Height
Height
Time
(in)
(in)
(ms)
0.170
0.250
400
0.180
0.275
500
0.190
0.300
600
0.200
0.350
700
0.220
0.375
800
0.240
0.400
1000
0.260
0.400
1000
0.270
0.400
1500
0.280
0.400
1500
Cutting
Pierce
Pierce
Height
Height
Time
(mm)
(mm)
(ms)
4.2
6.0
400
4.5
6.8
500
4.9
7.8
600
5.0
8.6
700
5.6
9.5
800
6.2
10.2
1000
6.6
10.2
1000
6.9
10.2
1500
7.1
10.2
1500
Arc
Travel Speed
Voltage
(volts)
(ipm)
(mm/min)
126
250
6350
WARNING
B-1
OPERATION
Kerf
Edge
Width
Start
(in)
0.147
0.148
0.148
0.150
0.150
0.155
0.160
0.170
0.180
Kerf
Edge
Width
Start
(mm)
3.7
3.8
3.8
3.8
3.8
4.0
4.1
4.3
4.6
Marking Height
Initial Height
(in)
(mm)
(in)
0.100
2.5
0.100
(mm)
2.5

Advertisement

Table of Contents
loading

Table of Contents