Lincoln Electric FlexCut 200 CE Operator's Manual page 49

Hide thumbs Also See for FlexCut 200 CE:
Table of Contents

Advertisement

®
FlexCut
200 CE
50 Amps - Stainless Steel - Air Plasma / Nitrogen Shield
Imperial
Plasma
Material Thickness
Pressure
(ga)
(in)
(psi)
14
0.075
12
0.105
11
0.120
66
10
0.135
3/16
0.188
1/4
0.250
Metric
Plasma
Material Thickness
Pressure
(mm)
(BAR)
2
4.55
2.5
3
5
6
Marking
Material
Plasma
All Thicknesses
(Plasma) (Shield) Amps
(psi)
Air
Nitroge
15
25
* Use an arc transfer height (ignition height) of .200" (5.1 mm) for cutting and .100" (2.5 mm) for marking.
Shield
Arc
Travel
Pressure
Voltage
Speed
(psi)
(ipm)
87
105
88
75
89
65
40
90
55
94
50
100
40
Shield
Arc
Travel
Pressure
Voltage
Speed
(BAR)
(mm/min)
2.76
87
2565
87
2080
88
1685
94
1235
98
1075
Shield
(BAR)
(psi)
(BAR)
1.72
40
2.76
Cutting
Pierce
Pierce
Height
Height
Time
(in)
(in)
(ms)
0.035
0.070
100
0.035
0.070
100
0.035
0.070
200
0.035
0.070
200
0.040
0.080
300
0.060
0.125
400
Cutting
Pierce
Pierce
Height
Height
Time
(mm)
(mm)
(ms)
0.9
1.8
100
0.9
1.8
100
0.9
1.8
200
1.0
2.1
400
1.3
2.9
400
Arc
Travel Speed
Voltage
(volts)
(ipm)
(mm/min)
108
250
6350
B-2
OPERATION
Kerf
Edge
Width
Start
(in)
0.105
0.105
0.105
0.110
0.110
0.115
Kerf
Edge
Width
Start
(mm)
2.7
2.7
2.7
2.8
2.9
Marking Height
Initial Height
(in)
(mm)
(in)
0.100
2.5
0.100
(mm)
2.5

Advertisement