INSTALLER SETUP
Settings
Minimum
The installer can select the
minimum run time for the
Compressor
compressor to help protect the
On-Time
compressor from short-cycling.
The compressor short cycle delay
Compressor
setting will not allow the compres-
Short Cycle
sor to be turned on for 5 minutes
after it was last turned off in order
Delay
to protect the compressor.
The cooling differential is factory
preset at 0.5°. This means that
whenever the room temperature
Cooling
heats by 0.5° full degree from the
temperature setting, the cooling
Differential
system will turn on. If the cooling
system turns on too often, increase
the temperature differential.
12
Display
Adjustment Options
The minimum compressor run time
can be adjusted from OFF to 3, 4, or
5 minutes. If 3, 4, or 5 is selected,
the compressor will run for at least
the selected time before turning off
(although the fan may continue to
run for a short time).
The compressor short cycle
delay setting can be removed by
selecting OFF.
The cooling differential setting is
adjustable from 0.2°F to 2°F.
Default
OFF
ON
0.5