Solving Problems
To execute the built-in performance verification test
The tests available through this command can be displayed as follows:
c>pv -l
Tests Available in Performance Verification;
Test # 1: Powerup PV Results
Test # 2: LAN 10Base2 Feedback Test
Test # 3: LAN 10BaseT Feedback Test
Test # 4: Break In and Trigger Out BNC Feedback Test
Test # 5: Target Probe Feedback Test
Test # 6: Boundary Scan Master Test
c>
The results on a good system are as follows:
c>pv 1
Testing: HPE3499A Series Emulation System
Test # 1: Powerup PV Results
Test # 2: LAN 10Base2 Feedback Test
Test # 3: LAN 10BaseT Feedback Test
Test # 4: Break In and Trigger Out BNC Feedback Test
Test # 5: Target Probe Feedback Test
Test # 6: Boundary Scan Master Test
PASSED
Number of tests: 1
Copyright (c) Hewlett-Packard Co. 1987
Copyright (c) International Business Machines Corp. 1995
All Rights Reserved.
written permission is prohibited, except as allowed under copyright laws.
HPE3499A Series Emulation System
Version:
A.06.00 14Feb96
Location:
Generics
HPE3494A PowerPC 603 (rev3) JTAG Emulator
Version:
A.01.04 28Feb96
?>
You may get an error like "!ERROR 172! Bad status code (0xff) from the hard
reset sequence" just before the prompt. This is because the selftest loopback
connector is installed instead of being connected to a real PowerPC target
system. You will also get either a "c>" or "?>" prompt for the same reason,
this is normal and expected. Any errors after the "PASSED Number of tests:
1 Number of failures: 0" line can be ignored.
88
Number of failures: 0
Reproduction, adaptation, or translation without prior
passed!
passed!
passed!
passed!
passed!
passed!