Testing Your Input Tools - Wacom CINTIQ 21UX Installation Manual & Hardware Manual

Hide thumbs Also See for CINTIQ 21UX:
Table of Contents

Advertisement

Cintiq21UX_Manual.fm Page 41 Friday, January 28, 2005 6:49 PM

Testing your input tools

If the Grip Pen, or the Cintiq ExpressKeys or Touch Strips do not work as you expect, it is a good idea to
first check the assigned functions or reset them to their default conditions. A quick way to reset a pen to
its default settings is to remove it from the T
been removed, place it back onto the display screen surface and the pen will be re-added to the T
list with its default settings.
Open the Wacom Tablet control panel and click on the A
click on the D
IAGNOSE
displays dynamic information about the Cintiq pen display tablet and pen. This information is used
when testing Cintiq and your input tool.
If more than one Cintiq unit is connected to your system, be sure to select the unit for which you are
testing in the T
ABLET
Note: When testing your tool buttons, if a button is set to P
function will occur when the button is pressed. In this case you may want to change that button's
function before testing.
Testing the ExpressKeys
1. With the D
IAGNOSTICS
ExpressKeys. If you have more than one Cintiq unit connected to your system, be sure to select
the unit you are testing from the T
2. Test the keys by clicking them one at a time. Each time you press a key, its number will be
displayed next to either the L
are testing.
When you are done, click the C
Testing the Touch Strips
1. With the D
IAGNOSTICS
Strip(s). If you have more than one Cintiq unit connected to your system, be sure to select the unit
you are testing from the T
2. Slide your finger up or down along the entire length of the Touch Strip you want to test. As you
touch and move your finger along the Touch Strip, a number will indicate the current finger position
for the respective Touch Strip next to L
When you are done, click the C
OOL
... button to open the D
IAGNOSTICS
I
column.
NFO
dialog box open, observe the T
I
ABLET
NFO
K
or R
EFT
EYS
button to exit the dialog box.
LOSE
dialog box open, observe the T
I
column.
ABLET
NFO
EFT
button to exit the dialog box.
LOSE
list by clicking on the list's [ – ] button. After the pen has
button. In the dialog box that appears,
BOUT
dialog box. The D
-
M
OP
UP
I
column as you test the
ABLET
NFO
column.
K
category, depending on which keys group you
IGHT
EYS
I
column as you test the Touch
ABLET
NFO
T
S
or R
T
OUCH
TRIP
IGHT
dialog box
IAGNOSTICS
or O
/R
..., that
ENU
PEN
UN
S
.
OUCH
TRIP
Troubleshooting
Page 41
OOL

Advertisement

Table of Contents
loading